Sign In | Join Free | My burrillandco.com
Home > Automation Control Components >

SIMATIC CPU 412 6ES7412-2EK07-0AB0 Central Processing Unit Industrial Automation Products

    Buy cheap SIMATIC CPU 412 6ES7412-2EK07-0AB0 Central Processing Unit Industrial Automation Products from wholesalers
     
    Buy cheap SIMATIC CPU 412 6ES7412-2EK07-0AB0 Central Processing Unit Industrial Automation Products from wholesalers
    • Buy cheap SIMATIC CPU 412 6ES7412-2EK07-0AB0 Central Processing Unit Industrial Automation Products from wholesalers
    • Buy cheap SIMATIC CPU 412 6ES7412-2EK07-0AB0 Central Processing Unit Industrial Automation Products from wholesalers
    • Buy cheap SIMATIC CPU 412 6ES7412-2EK07-0AB0 Central Processing Unit Industrial Automation Products from wholesalers

    SIMATIC CPU 412 6ES7412-2EK07-0AB0 Central Processing Unit Industrial Automation Products

    Ask Lasest Price
    Brand Name : SIEMENS
    Model Number : 6ES7412-2EK07-0AB0
    Price : EXW USD3510-3550
    Payment Terms : T/T, Western Union,Paypal
    Supply Ability : 100PCS Every month
    Delivery Time : 15-30 work days
    • Product Details
    • Company Profile

    SIMATIC CPU 412 6ES7412-2EK07-0AB0 Central Processing Unit Industrial Automation Products

    SIEMENS SIMATIC CPU 412 6ES7412-2EK07-0AB0 Industrial Automation Products Central Processing Unit

    Application

    The CPU 412-1 is the low-cost entry into the medium performance range. It can be used in smaller systems with limited I/O configuration. The combined MPI/DP interface also enables operation of a PROFIBUS DP line.

    The CPU 412-2 is the CPU for applications in the mid-performance range with 2 PROFIBUS DP master systems.

    For networking within a PROFINET network, the CPU 412-2 PN is available.

    Function
    • Block protection:
      A password concept also protects the user program from unauthorized access
    • Integrated HMI services:
      The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
    • Integrated communication functions:
      • PG/OP communication
      • Global data communication
      • S7 standard communication
      • S7 communication
    Programmable properties

    The STEP 7 tool "Hardware configuration" can be used to parameterize the properties and response of the S7-400 including the CPUs, e.g.

    • Multipoint interface MPI:
      • Definition of node addresses
      • Startup/cycle behavior
      • Stipulation of the maximum cycle time and communication load
    • Address allocation:
      Addressing of I/O modules
    • Retentive area:
      Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories
    • Size of the process image, local data
    • Length of the diagnostics buffer
    • Protection level:
      Definition of access authorizations to program and data
    • System diagnostics:
      Definition of the handling and scope of diagnostics messages
    • Timed interrupts:
      Setting of periodicity
    Display and information functions
    • Status and fault indicators:
      LEDs indicate internal and external faults and operating modes such RUN, STOP, restart, test function, etc.
    • Test functions:
      The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components.
    • Information functions:
      The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.

    Technical specifications

    Article number

    6ES7412-1XJ07-0AB0

    6ES7412-2XK07-0AB0

    6ES7412-2EK07-0AB0


    CPU412-1, MPI/DP, 512 KB

    CPU412-2, MPI/DP, 1 MB

    CPU412-2 PN, 1 MB, 2 SCHNITTSTELLEN

    General information
    Product type designationCPU 412-1CPU 412-2CPU 412-2 PN
    HW functional status010101
    Firmware versionV7.0V7.0V7.0
    Engineering with
    • ● Programming package

    STEP 7 V5.4 or higher with HSP 261STEP 7 V5.4 or higher with HSP 261STEP 7 V5.5 or higher with HSP 262
    CiR – Configuration in RUN
    CiR synchronization time, basic load100 ms100 ms100 ms
    CiR synchronization time, time per I/O byte30 µs30 µs30 µs
    Supply voltage
    Rated value (DC)
    • ● 24 V DC

    No; Power supply via system power supplyNo; Power supply via system power supplyNo; Power supply via system power supply
    Input current
    from backplane bus 5 V DC, typ.0.7 A0.9 A1.1 A
    from backplane bus 5 V DC, max.0.8 A1.1 A1.4 A
    from backplane bus 24 V DC, max.150 mA; 150 mA per DP interface300 mA; 150 mA per DP interface150 mA; 150 mA per DP interface
    from interface 5 V DC, max.90 mA; At the DP interface90 mA; At each DP interface90 mA; At the DP interface
    Power loss
    Power loss, typ.3.5 W4.5 W5.5 W
    Power loss, max.4 W5.5 W7 W
    Memory
    Type of memoryRAMRAMRAM
    Work memory
    • ● integrated

    512 kbyte1 Mbyte1 Mbyte
    • ● integrated (for program)

    256 kbyte512 kbyte512 kbyte
    • ● integrated (for data)

    256 kbyte512 kbyte512 kbyte
    • ● expandable

    NoNoNo
    Load memory
    • ● expandable FEPROM

    Yes; with Memory Card (FLASH)Yes; with Memory Card (FLASH)Yes; with Memory Card (FLASH)
    • ● expandable FEPROM, max.

    64 Mbyte64 Mbyte64 Mbyte
    • ● integrated RAM, max.

    512 kbyte512 kbyte512 kbyte
    • ● expandable RAM

    Yes; with Memory Card (RAM)Yes; with Memory Card (RAM)Yes; with Memory Card (RAM)
    • ● expandable RAM, max.

    64 Mbyte64 Mbyte64 Mbyte
    Backup
    • ● present

    YesYesYes
    • ● with battery

    Yes; all dataYes; all dataYes; all data
    • ● without battery

    NoNoNo
    Battery
    Backup battery
    • ● Backup current, typ.

    180 µA; up to 40 °C180 µA; up to 40 °C180 µA; up to 40 °C
    • ● Backup current, max.

    850 µA850 µA850 µA
    • ● Backup time, max.

    Dealt with in the module data manual with the secondary conditions and the factors of influenceDealt with in the module data manual with the secondary conditions and the factors of influenceDealt with in the module data manual with the secondary conditions and the factors of influence
    • ● Feeding of external backup voltage to CPU

    5 V DC to 15 V DC5 V DC to 15 V DC5 V DC to 15 V DC
    CPU processing times
    for bit operations, typ.31.25 ns31.25 ns31.25 ns
    for word operations, typ.31.25 ns31.25 ns31.25 ns
    for fixed point arithmetic, typ.31.25 ns31.25 ns31.25 ns
    for floating point arithmetic, typ.62.5 ns62.5 ns62.5 ns
    CPU-blocks
    DB
    • ● Number, max.

    3 000; Number range: 1 to 160003 000; Number range: 1 to 160003 000; Number range: 1 to 16000
    • ● Size, max.

    64 kbyte64 kbyte64 kbyte
    FB
    • ● Number, max.

    1 500; Number range: 0 to 79991 500; Number range: 0 to 79991 500; Number range: 0 to 7999
    • ● Size, max.

    64 kbyte64 kbyte64 kbyte
    FC
    • ● Number, max.

    1 500; Number range: 0 to 79991 500; Number range: 0 to 79991 500; Number range: 0 to 7999
    • ● Size, max.

    64 kbyte64 kbyte64 kbyte
    OB
    • ● Number, max.

    see instruction listsee instruction listsee instruction list
    • ● Size, max.

    64 kbyte64 kbyte64 kbyte
    • ● Number of free cycle OBs

    1; OB 11; OB 11; OB 1
    • ● Number of time alarm OBs

    2; OB 10, 112; OB 10, 112; OB 10, 11
    • ● Number of delay alarm OBs

    2; OB 20, 212; OB 20, 212; OB 20, 21
    • ● Number of cyclic interrupt OBs

    2; OB 32, 35 (shortest cycle that can be set = 500 µs)2; OB 32, 35 (shortest cycle that can be set = 500 µs)2; OB 32, 35 (shortest cycle that can be set = 500 µs)
    • ● Number of process alarm OBs

    2; OB 40, 412; OB 40, 412; OB 40, 41
    • ● Number of DPV1 alarm OBs

    3; OB 55-573; OB 55-573; OB 55-57
    • ● Number of isochronous mode OBs

    2; OB 61-622; OB 61-622; OB 61-62
    • ● Number of multicomputing OBs

    1; OB 601; OB 601; OB 60
    • ● Number of background OBs

    1; OB 901; OB 901; OB 90
    • ● Number of startup OBs

    3; OB 100-1023; OB 100-1023; OB 100-102
    • ● Number of asynchronous error OBs

    9; OB 80-889; OB 80-889; OB 80-88
    • ● Number of synchronous error OBs

    2; OB 121, 1222; OB 121, 1222; OB 121, 122
    Nesting depth
    • ● per priority class

    242424
    • ● additional within an error OB

    111
    Counters, timers and their retentivity
    S7 counter
    • ● Number

    2 0482 0482 048
    Retentivity
    • — adjustable

    YesYesYes
    • — lower limit

    000
    • — upper limit

    2 0472 0472 047
    • — preset

    Z 0 to Z 7Z 0 to Z 7Z 0 to Z 7
    Counting range
    • — lower limit

    000
    • — upper limit

    999999999
    IEC counter
    • ● Number

    Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)
    S7 times
    • ● Number

    2 0482 0482 048
    Retentivity
    • — adjustable

    YesYesYes
    • — lower limit

    000
    • — upper limit

    2 0472 0472 047
    • — preset

    No times retentiveNo times retentiveNo times retentive
    Time range
    • — lower limit

    10 ms10 ms10 ms
    • — upper limit

    9 990 s9 990 s9 990 s
    IEC timer
    • ● present

    YesYesYes
    • ● Type

    SFBSFBSFB
    • ● Number

    Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)
    Data areas and their retentivity
    retentive data area in totalTotal working and load memory (with backup battery)Total working and load memory (with backup battery)Total working and load memory (with backup battery)