Description:
Used for Italy Autel pulse jet valves.
We use high quality material , the collection equipment efficiency
can be improved , the energy loss also can be reduced.
The working frequency is stable
Its lifespan is about 1 million cycles.
Voltage: DC24V
Power: 17W
1 . The pulse diaphragm valves are especially designed for dust
collector service applications, combining high flow, long life and
extremely fast opening and closing to produce reliable and
economical operation.
2 . The high flow, angle type bodies in combination with the
special main diaphragm assemblies give the unique operating
features required for dust collector service applications
3 . The design with integral compression fittings will facilitate
installation because there is no need for threaded piping
4 . The high quality diaphragms are reinforced and wear resistant
to guarantee a long operating life, even under harsh conditions
5 . Integral pilot operated valves satisfy all relevant EC
directives
Construction | |
Body | Aluminum (Diecast) |
Washer | SS 304 |
Armature | SS 430FR |
Core and Plugnut | Stainless steel |
Core Spring | SS 304 |
Sealing & disc | NBR(nitrile/buna-n) |
Screws | SS302 |
Diaphragm | PA-6(Standard), fluororubber |
Connector | Pg9 IP65 |
Voltage | 230-150-24 V / 50-60 HZ AC 24 V DC |
Working Temperature | -20 to +85℃ Nitrile seals -29 to +232℃ fluororubber seals |
Power Absorption | 17 VA AC / 17 W DC |
Conn.Insulation class | C-VDE 0110 |
Connector specification | Din 43650 – IS0 4400 |
Max Pressure | 8 Bar |
Recommended on time range | 50-500ms |
Recommended time between pulses | 1 minute or Less |
General Description
In the high efficiency series we can include the range of flat
surface valves. These valves, used for cleaning
filter elements in air filtration systems, are specifically
designed for flat surfaces like square header tanks and
flanged tank. Like traditional model, with threaded and coupling
connection, the activating can be:
Integrated the pilot is placed on the valve and the excitation
(electric) is made by a coil.
Remote: the pilot is remote and the excitation is pneumatic. The
connection between pilot and valve is made by
a simple pneumatic tube.
All That is achieved from a deep studying of internal geometrical
characteristics and from a
technological research on diaphragm. This guarantees rapid
opening-closing cycles and a working for
over a million of shots.
Introduction
Electromagnetic pulse valve refers to the gas through the valve in
instantaneous once a electrical signal received. Just like pulse
phenomena, it has the change of the short fluctuation. Therefore it
is calls the pulse valve. The Industry standard definition of
electromagnetic pulse valve for electromagnetic pilot valve and
pulse valve together, diaphragm valve controlled by electrical
signals.
Competitive Advantage:
Our product features: | Our Services Guarantee: |
1) Competitive price | 1) Prompt respond (Reply with 24 hours) |
2) Good quality | 2) Free Samples (Customer pay for the delivery cost) |
3) Professional Packaging, | 3) Registration support. |
4) Produce according to Customers’ instruction | 4) Photos/videos are available during production. |
5) None delay shipment | 5) Loading inspection, and send loading photos before shipment. |
Quality Standards :
The company for the products are brand new original products, no
second-hand and refurbished products, or leave a compensable ten
and return the full amount , but the buyer due to our purchase of
model error is not responsible for returns, another of the
company's sales of products enjoy one year from the date of
shipment quality assurance , according to the original quality
standards , during warranty with product problems , need
confirmation testing by the manufacturer , the supplier to be
solved , the demand side due to storage , use, poor maintenance
caused by lower-quality product , and not raise objections
Warranty:
All item Comes with Basic 3 Month Sellers Warranty, if item
defective in 3 Month, We will offer replacement without extra
Charger(including shipping fee)After we Receive the Defective item.
If item Defective after 3 Month, Buyers can still send it back, We
will contact suppliers or Manufactory for Warranty. Buyers Might
Need to pay the Shipping fee For resend the replaced item.
Introduction
Electromagnetic pulse valve refers to the gas through the valve in
instantaneous once a electrical signal received. Just like pulse
phenomena, it has the change of the short fluctuation. Therefore it
is calls the pulse valve. The Industry standard definition of
electromagnetic pulse valve for electromagnetic pilot valve and
pulse valve together, diaphragm valve controlled by electrical
signals.
Working principle
Electrical pulse controller send input signals so that the
electromagnetic armature attracts the moving bar. Unclose the
balancing hole to release the pressure gas in the back cavity of
diaphragm quickly; the pressure gas in the front cavity holds up
the diaphragm to open the passage and the valve starts cleaning.
The pulse signal disappears and the spring of the armature works
immediately to resume the moving bar so as to close the balancing
hole. The pressure gas in the back cavity of the diaphragm and the
spring work together to close the passage the valve stops cleaning.
The damping hole in the diaphragm functions to damp the airflow
when the moving bar of armature holds up for balancing and to
transit the air to the back cavity as soon as the balancing hole is
shut to close the passage and stop cleaning.
The installment introduction:
1. First, Confirm the pulse valve in good condition and then
installed
2. Pulse valve will be installed directly the outer wall of flange
of gas manifold. The spray pipe across the gas manifold. According
to the drawing and manual, the pulse valve matching appropriate
spray pipe and installation. To avoid the valve install in the air
manifold bottom. If the pulse valve matched trachea and connector,
the connector will be used for sealing purpose only. It can not as
structural support components. It can not rely on the straight
connector fixed spray torch and package. The spray pipe and air
manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten
the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric
control valve seat. Pay attention to the line adown to prevent rain
waterproof. Or through the joint and nylon pipe, it will connect
the pulse valve and electromagnetic assembly boxes of nylon pipe
connection.
5. To ensure that provide compressed air clean and dry. The air
manifold system provides moderate pressure and check for leaks
installation. ( it can brush on soap and water, check whether the
interface is bubble). Pressure was carried out on the air bag
inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa),
recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve
whether it is normal operation and whether the pulse blowing sound
is clear.
![]() |